Description
The Diagnostic kit includes:
1. Diagnostic Pro Sense, shoulder.
2. Diagnostic NC Pro, non-contact infrared.
1. Diagnostic Pro Sense, upper arm blood pressure monitor:
A blood pressure monitor designed to measure blood pressure and pulse, ideal for people with unstable blood pressure, overweight, diabetes and chronic diseases such as chronic kidney disease or COPD.
Why choose the Pro Sense blood pressure monitor?
- A clear display makes it easy to read the results.
- Measurement with one button - fast and convenient.
- Detects incorrectly applied cuff and body movement during measurement.
- Measures irregular heart rate (IHB).
- WHO blood pressure classification index.
- Possibility to save measurements for 2 users.
- Universal arm cuff.
- Battery powered or possible to operate with a mains adapter (optional).
The Diagnostic Pro Sense upper arm blood pressure monitor is a reliable device for daily blood pressure control. Easy to use, precise and adapted to the needs of various users - it ensures convenience and accuracy of measurements.
Application
A blood pressure monitor designed to measure blood pressure and pulse in patients:
- with unstable pressure (MAC function),
- overweight and diabetic,
- with chronic kidney disease,
- with COPD.
How to use
- Place the cuff about 1-2 cm above the elbow. For best results, place the cuff on your bare arm, at heart level.
- Press and hold the button until you hear a beep.
- First, it is pumped to the initial pressure. If the current user's systolic pressure is greater than 190 mmHg, the device will automatically adjust the inflation to the appropriate level.
- Once the cuff is inflated, the air will slowly deflate as indicated by the blood pressure monitor. At the same time, a heart symbol will flash on the screen, indicating a heartbeat.
- After the measurement is completed, you will hear three short beeps.
- The screen will display the systolic and diastolic blood pressure values.
- The WHO blood pressure indicator will appear on the left side of the screen.
- Press the button to turn off the device in any mode or leave it on, and the blood pressure monitor will turn off automatically after about 3 minutes of inactivity.
Product features
- clear display,
- measurement made with one button,
- detects incorrectly applied cuff,
- detects body movement during measurement,
- measures irregular IHB pulse,
- Blood Pressure Classification Index according to the World Health Organization (WHO),
- remembers measurements for 2 users,
- easy-to-use arm cuff in a universal size (22-42 cm),
- battery powered, ability to work with a power supply (optional),
- automatic switch off after 3 minutes,
- low battery indication.
Technical specifications
- Measurement method: oscillometric.
- Measurement range:
- pressure: 30-280 mmHg;
- pulse: 40-199 beats/minute.
- Measurement accuracy:
- pressure: ±3 mmHg;
- Pulse: ±5%.
- Irregular pulse: measurement with irregular IHB pulse.
- Cuff: 22-42 cm.
- Cuff inflation: automatic inflation device.
- Cuff deflation: automatically by air valve.
- Display: digital LCD.
- Power supply: alkaline batteries x 4 pcs (AA) or DC 6V, 600 mA, 3.6W power supply.
- Operating conditions: 5 to 40°C; humidity 10-95% RH.
- Transport and storage: -10 to -55°C; <95% RH.
- Optional equipment (additionally paid): L cuff (32-42 cm), power supply.
- Dimensions: 135 x 90 x 41 mm.
- Weight: 365 g.
Guarantee
- 2 years for cuff,
- 5 years for the blood pressure monitor.
Warnings
- Using a cuff other than the recommended one may result in measurement errors.
- Do not use the blood pressure device on infants.
- Do not use the device in pregnant patients with preeclampsia.
- Be careful not to entangle the cables to avoid serious injury to the patient or disturbance of blood pressure measurement.
- Too frequent measurements may cause injury to the patient due to disruption of blood flow.
- Applying a cuff to the wound may make it worse.
- Applying the cuff to the arm that is being treated may cause injury by temporarily obstructing blood flow as the pressure is increased.
- Do not apply or inflate the cuff on the side where the mastectomy was performed.
- Inflation of the cuff may temporarily stop vital signs monitoring equipment being used on the same arm.
- Blood pressure measurement with an automatic blood pressure measuring device does not cause long-term impairment of the patient's blood circulation.
- The device is not suitable for simultaneous operation with high frequency (HF) electrosurgical equipment.
- Self-measurement means control, not diagnosis and treatment. Abnormal values should always be consulted with your doctor. Under no circumstances should you change the doses of medicines prescribed by your doctor.
- The displayed heart rate is not suitable for monitoring the heart rate of a pacemaker.
- In the case of arrhythmia, the measurement made using the device should be consulted with a doctor.
- The air hose or power cord may pose a choking hazard to infants.
- Keep out of the reach of children and pets.
- Small parts of the kit pose a choking hazard if swallowed.
- The device should not be used on infants or people who are unable to communicate.
- The device contains sensitive electrical components, therefore strong electric or electromagnetic fields should be avoided in its vicinity (e.g. mobile phones, microwave ovens). Otherwise, the measurement accuracy may be temporarily impaired.
- This device may only be used for its intended purpose as described in the instructions for use. The manufacturer is not responsible for damage caused by incorrect use of the device.
- The device contains sensitive components and must be handled with care. The storage and use conditions must be observed (technical data)
- Protect your device from water and moisture, extreme temperatures, impacts, drops, dust, direct sunlight, heat and cold.
- Inflate the cuff only after it is on.
- Do not use the device near electromagnetic fields generated by mobile phones and radio installations.
- Do not use the device if it is damaged.
- If the device will not be used for a long time, remove the batteries.
- Only original components supplied by the Manufacturer should be used.
- The use of other components may reduce the level of security.
- Never repair the device yourself.
Package contents
- Diagnostic Pro Sense blood pressure monitor.
- Universal cuff.
- 4 AAA batteries.
- Instructions for use.
- Case.
Producer
DiagnosisSA
street Gen. W. Andersa 38A
15-113 Białystok, Poland
2. Diagnostic NC Pro, non-contact infrared thermometer:
The Diagnostic NC Pro non-contact infrared thermometer is a device for the whole family. It enables non-contact measurement of body temperature even during sleep. It provides accurate and reliable measurement in a very short time. After turning on the device, the last recorded result is displayed. The thermometer warns the user about increased body temperature with a sound signal and red screen backlight. The thermometer turns off automatically within 1 minute.
Application
Body temperature measurement.
Product features
- non-contact body temperature measurement,
- ambient temperature measurement,
- high temperature alarm,
- backlit display,
- quick measurement.
Technical specifications
- measurement time: 1 second,
- memory: 12 measurements,
- power supply: 2 AAA batteries,
- dimensions: 141 x 36 x 37 mm,
- measurement site: forehead and surroundings,
- operating conditions: 15~40°C (59~104°F), humidity: 15~95%, pressure: 800-1060 hPa,
- storage and transport conditions: -20~50°C (-4~122°F), humidity: 15~95%, pressure: 800-1060 hPa,
- IP classification: IP22,
- measurement distance: about 8 cm,
- automatic shutdown: within 1 minute.
Guarantee
2 years
Warnings
- When you develop a fever, consult your doctor instead of self-diagnosing.
- Any modifications to the device are prohibited.
- The thermometer should not be exposed to mechanical influences and should not be used if it is damaged.
- Do not immerse the device in water or other liquids.
- Do not use the device near sources of high-frequency electromagnetic radiation, for example near wireless sources or mobile phones.
- Children should not be allowed to play with the thermometer.
- Do not expose the thermometer to direct sunlight, heat, moisture or dirt.
- Replace batteries if necessary.
- The ambient temperature in the apartment may vary depending on the room.
- Before measuring the temperature, the user and the thermometer should remain in the same room(s) with constant environmental conditions for at least 15 minutes.
- Before starting the measurement, remove dirt, sweat and hair from the measurement area.
- Do not take your temperature during or immediately after feeding.
- The user should not consume food or drink immediately before or during the temperature measurement.
- Do not put the thermometer in your pocket before use because it may become hot.
- Each time, before starting a measurement, make sure that the lenses of the measurement sensors are not dirty. If dirty, clean them.
- In the early stages of the disease with a sharp increase in temperature to high values, the effect of "white hyperthermia" is observed - a condition characterized by vasoconstriction, and the skin becomes pale and remains cold. In such cases, it should not be carried out
temperature measurements on the forehead as the skin temperature will be low. - The thermometer should be kept away from children and pets.
- Temperature measurement should be performed under the supervision of an adult. Do not allow a child to remove the battery cover or remove or swallow the battery.
- After transportation or cold storage, keep the device at room temperature for at least 2 hours to bring it to ambient temperature before turning it on. Then take the measurement.
Package contents
- Thermometer.
- 2 AAA batteries.
- Instructions for use.
- Case.
Producer
DiagnosisSA
street Gen. W. Andersa 38A
15-113 Białystok, Poland
Features
Product code | 430310 |
Category | Sphygmomanometers, Medical equipment |
Delivery from | Poland |
Reviews
All reviews