Vital Function Monitor Contec CMS9000
Description
- \n
- 12.1-inch TFT LCD screen with a resolution of 800x600 pixels \n
- 3 warning LEDs: 1 alarm LED (orange/red), 1 power supply LED (green), 1 battery charge LED (yellow) \n
- Display a maximum of 8 waveforms \n
- Intuitive interface with display in several languages, including Romanian. \n
- The controls are operated by means of ergonomic keys and buttons \n
- ECG: on 2 channels 7 leads: I, II, III, avR, avL, AvF, V \n
- 7 ECG leads can be displayed on the screen simultaneously \n
- Heart rate: 15-300 bpm. SpO2:0-100%, accuracy: ±2% between 7-100%. \n
- Analysis of arrhythmias and ST segment \n
- Limit values: 10-270 Hgmm \n
- Respiration: 0-120/min adults, 0-150/min in children \n
- Temperature measurement limits: 0-50 °C \n
- Blood pressure is measured with the oscillometric method manually, automatically or continuously \n
- Memory for 500 TA values, 72 alarm situations (with all parameters) \n
- Heart rate variability (HRV) analysis function \n
- Alarm: sound (3 sound modes corresponding to the alarm mode) and visual \n
- The parameters can be reviewed graphically and tubularly for the last 72 hours \n
- View 71 alarm events for all parameters and 60 arrhythmia alarm events \n
- Calculation of the concentration of prescribed drugs \n
- Date, wave color adjustable \n
- Fanless design (quiet operation) \n
- System with low energy consumption \n
- Due to its shape, the possibility of cross-contamination is reduced, making it easy to clean and handle \n
- Rechargeable Lithium battery of 3500mAh, 7.4V \n
- It can be used in the network. \n
- \n
- Reference channel selection: I, II, III, aVR, aVL, aVF, V \n
- Waveform: 2 channels \n
- \n
- Reference channel selection: I, II, III, \n
- Waveform: 1 channel \n
- Measurement and Alarm Range for the ST segment: – 2.0 mV ̴ + 2.0 mV \n
- Sensitivity: 2.5 mm/mV, 5.0 mm/mV, 10 mm/mV, 20 mm/mV, 40 mm/mV \n
- Scanning speed: 12.5mm/s, 25mm/s, 50mm/s \n
- Measurement and Alarm Range for HR: Adult 15 ~ 300 bpm; Neonatology/Pediatrics 15 ~ 350 bpm \n
- Accuracy ± 1% or ± 1bpm \n
- Resolution 1 bpm \n
- Sensitivity> 200 uV PP \n
- Differential input impedance > 5 MΩ \n
- \n
- Method: Impedance between RF (RA-LL) \n
- Differential input impedance: > 2.5 MΩ \n
- Impedance measurement range: 0.3 ~ 5.0Ω \n
- Baseline Impedance Range: 0.1 KΩ– 2.5 KΩ \n
- Bandwidth: 0.3 ~ 2.5 Hz \n
- Scanning speed: 6.25mm/s, 12.5mm/s, 25mm/s \n
- \n
- Measurement and alarm range: Adult 0 ~ 120 rpm; Neonatology/Pediatrics 0 ~ 150 rpm \n
- Resolution: 1 rpm \n
- Accuracy: ± 2 rpm \n
- Apnea alarm: 10~40s \n
- Alarm limit interval (rpm) \n
- High alarm limit: (low limit + 1) ~ 150 \n
- Low limit alarm: Adults: 0 ~ (high limit-1) - Pediatrics and newborn: 0 ~ (high limit-1) \n
- Alarm limit interval Step (rpm): 1 \n
- \n
- Measuring range 0 ~ 100% \n
- Alarm range 0~100% \n
- resolution 1% \n
- Accuracy: 70% ~ 100% ± 2%; 0% ~ 69% - unspecified \n
- Update interval: about 1Sec. \n
- Alarm delay: 10 sec. \n
- Scanning speed: 12.5mm/s, 25mm/s \n
- \n
- Measurement and alarm range 30 ~ 250bpm \n
- 1bpm resolution \n
- Accuracy ± 2bpm \n
- \n
- Method: Oscillometric \n
- Modes: Manual/AUTO/Continuous \n
- Measurement interval in AUTO mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 960 Min \n
- Measurement period in Continuous mode: 5 minutes \n
- Alarm type SYS, DIA, Environment \n
- \n
- SYS 40 ~ 270 mmHg \n
- DIA 10 ~ 215 mmHg \n
- Average 20 ~ 235 mmHg \n
- \n
- SYS 40 ~ 200 mmHg \n
- DIA 10 ~ 150 mmHg \n
- Average 20 ~ 165 mmHg \n
- \n
- SYS 40 ~ 135 mmHg \n
- DIA 10 ~ 100 mmHg \n
- Average 20 ~ 110 mmHg \n
- \n
- Pressure 1mmHg \n
- \n
- Average error: ± 5mmHg \n
- Maximum standard deviation: 8mmHg \n
- \n
- Adult mode: 297 ± 3 mmHg \n
- Pediatric mode: 240 ± 3 mmHg \n
- Neonatal mode: 147 ± 3 mmHg \n
- \n
- Channels: Dual Channels \n
- Measurement and alarm range 0 ~ 50 ℃ \n
- Resolution 0.1 ℃ \n
- Accuracy ± 0.1℃ \n
- Update interval about 1 sec. \n
- Constant average time <10 sec. \n
- \n
- Dimensions: 319mm (L) x 161mm (W) x 269mm (H) \n
- Weight: 3.6 Kg \n
- \n
- Operation 5~40 (°C) \n
- Transport and storage -40~55 (°C) \n
- \n
- Operation 30-75% \n
- Transport and storage ≤ 95% \n
- \n
- Operation: between -500 and 4,600 m \n
- Transport and storage: between -500 and 13,100 m \n
- \n
- FUSE T 1.6A \n
- \n
- Operating time under conditions of normal use and full charge greater than 90 minutes \n
- The operating time after the first low battery alarm will be approximately 5 minutes \n
- Charging: up to 90% after charging 4 hours, fully charged after 5 hours \n
- \n
- ECG patient cable 5 derivations; \n
- Disposable ECG electrodes; \n
- Clamp type SpO2 sensor for adults; \n
- Temperature sensor with cable; \n
- Adult cuff for arm with a circumference of 25-35 cm.; \n
- Cuff connector tube \n
Features
| Product code | 516408 |
| Category | Medical Equipment and Medical Supplies |
| Brand | Contec |
| Delivery from | Romania |
Vital Function Monitor Contec CMS9000
Vital Function Monitor Contec CMS9000